Cooler has an appropriate structure for production of livestock, poultry, and aquatic feed with proper moisture content and high shelf-life. Vertical cooling of the produced granules prevents cracks in the products and improves the product quality up to 5%.
This machine is designed in capacities of 5-30 tons and manufactured in accordance with consumers’ needs.
Cooler
Special features of this device :
Suitable design to occupy less space
Suitable design to occupy less space
Uniform distribution and cooling of materials in different sections of the device
Uniform distribution and cooling of materials in different sections of the device
No wasted space due to the unique design of the device frame
No wasted space due to the unique design of the device frame
Adjustable vibrating discharge velocity
Adjustable vibrating discharge velocity
Uniform discharge, stable movement, full discharge of granules from the tank, and output temperature close to the ambient temperature
Uniform discharge, stable movement, full discharge of granules from the tank, and output temperature close to the ambient temperature
Cooler malfunction and troubleshooting
Trouble/s Cause/s Solution/s Poor cooling effect Insufficient time of cooling due to high rate of feeding; Insufficient time of cooling due to thin material bed;
Too large pellets;
The air inlet does not open sufficiently;
Consult with a specialized technician in this regard. Readjust the position of the level indicator;
Check the status of the air inlet again
Hollow space is seen in the material Uneven distributed material leading to short interruption of the airflow; The air inlet opens extensively and the air speed is high when the pellets are in small sizes.
Check the status of the air inlet again