Some tips about the cooler malfunction and troubleshooting
See some tips about the cooler malfunction and troubleshooting in the following table.
Trouble/s | Cause/s | Solution/s |
Poor cooling effect |
Insufficient time of cooling due to high rate of feeding;
Insufficient time of cooling due to thin material bed; Too large pellets; The air inlet does not open sufficiently; |
Consult with a specialized technician in this regard.
Readjust the position of the level indicator; Check the status of the air inlet again; Strengthen the ID fan. |
Hollow space is seen in the material | Uneven distributed material leading to short interruption of the airflow;
The air inlet opens extensively and the air speed is high when the pellets are in small sizes.
|
Check the status of the air inlet again |
*Deep clean the inside part of the machine after each production. All ball bearings and wheels should be inspected and greased.
*The ID fan healthy condition and its lack of vibration should be reported.
* Warning: All machinery should be repaired, modified, and regulated after the main power board is cut off.